Dear Smart Construction 3D Machine Guidance Users
We would like to inform you of a bug that was found in Smart Construction Pilot (Tablet App) v1.0.08 released on June 19, 2024 (Wednesday), and in the previous version ~v1.0.07.
*On Wednesday, July 17, 2024, we will release v1.0.08.1 of the following bug fix application on Google Play Store.
Issue:
The display of the loading weight is inconsistent even after "Unloaded Calibration" is performed.
Cause:
When "Unloaded Calibration" on the "Payload Meter" application is performed two or more times, the correct value is not entered in the Payload Meter Correction formula B.
Permanent fix:
Please use the latest ver after the release of the bug fix application v1.0.08.1.
Temporary fix (old version):
- Temporary Action
It is possible to avoid this problem by manually inputting 0 to the correction value B before the unloaded calibration. After inputting 0 to the correction value B, be sure to perform the unloaded calibration only once.
How to operate the tablet
Menu > Basic Settings > (Machine symbol) > Password A (enter 31415) > Machine Settings >
Correction formula
Enter 0 to item B > Update with ✓ in the lower right corner.
We are currently working on improving the application so that we can release a permanent fix version v1.0.08.1. Until the improvement is made, please enter 0 in the Correction Formula B as described above and start the application again.
Comments
0 comments
Please sign in to leave a comment.